Analysis of Reinforced Concrete Building for Strong Column and Weak Beam BehaviourAuthors: Swapnil Nayan,Pradeep Kumar Ramancharla Conference: USMCA-2018: 17th International Symposium on New Technologies for Urban safety of Megacities in Asi (USMCA 2018 2018) Date: 2018-12-12 Report no: IIIT/TR/2018/89 AbstractDuring earthquake, building failure occurs due to the failure of Columns under lateral load. To avoid this, seismic design of building requires the formation of plastic hinges in beams before plastic hinges form in columns. This mechanism is often referred to as “Strong Column - Weak Beam” Mechanism. This paper deals with the analysis of Strong Column and Weak Beam mechanism in Reinforced Concrete buildings by analysing the effects of ‘Area moment of Inertia’, ‘Reinforcement’ and ‘lengths’ of members of the buildings. The condition for Strong Column and Weak beam given in IS 13920:2016 i.e. ratio of summation of moments of columns to that of a beams at a joint should be greater than or equal to 1.4 is also verified. Full paper: pdf Centre for Earthquake Engineering |
||||||||